DESCRIPTION

The shunts are designed to comply with the requirements of IS1248 / DIN43703 & DIN43780. The shunt provides an accurate d.c. millivolt signal, exactly proportional to the system current

 

FEATURES
Rating 1A to 15000A
Riveted and soldered construction
In-line bus bar mounting
Very low temperature coefficient
High overload withstand
Shock and vibration Proof
Long term stability

 

TYPE
1) Insulated mounting

2) "I" Section 

3) "L" Section 


4) "T" Section
Ranges
1, 1.5,2,2.5, 3,4,5,6, 10, 15,20,25, 30 Amp.

30, 40, 50, 60, 75, 80, 100, 120, 150Amp.

200, 250, 300, 400, 500, 600, 750, 800, 1000,
1200, 1500, 2000, 2500, 3000Amp. 

4000, 5000, 6000, 7500, 8000, 10000, 12000, 15000Amp.
ACCURACY ± 0.5%
CONTINUOUS 
OVER LOAD
20% rated current
5 SECONDS WITHSTAND 10 times for 1 A to 500 Amp. 
5 times for 600A to 2000Amp. 
2 times for 2500A to 15000Amp.
TEMP. COEFFICIENT 0.002% per °C.
AMBIENT TEMP. Calibration at 23°C.
OPERATING TEMP. -10°C to 55°C.
STORAGE TEMP. -20°C to 70°C
MAXIMUM LOAD The load should not exceed 0.1% of the nominal current rating 
for specified accuracy.
MILLIVOLT 50mV, 60mV, 75mV, l00mV, 150mV, 300mV (standard)
Other mV outputs on request.

 

NOTE :

Two cables of 1 meter length with 1.5mm cross sectional area are provided. This corresponds to a total resistance of 0.026 ohms. The instruments are calibrated with this resistance and consequently the cable length must not be changed. If different length or resistances are required, please indicate while ordering.

 

INSTALLATION
The best performance is guaranteed if the following points are observed.
1) Shunts may be mounted horizontally or vertically. Horizontal mounting gives the best heat dissipation.
2) Utilize the full end block surface area.
3) Ample ventilation should be provided.
4) Busbar should be adequately rated, cleaned & coated with a thin layer of silicon grease applied to the contact surface area.
5) Bolts and nuts must be carefully tightened.

 

CAUTION
Shunts are not insulated & protection against accidental contact may be necessary in order to comply with Health & Safety regulations.

 

Ordering information
1) Current rating 2) Millivolt output 3) Length of the cable

 

Rated Current 
Amps.
Dim 'A' Max. Dim
'B1'
Dim
'B2'
Dim
'B3'
Dim
'C1'
Dim 'E' Dim 'H'
(mV) (mV) (mV)
60 75 100 150 300 60 75 100 150 300 60/75 100~300
1~30 90 90 90 90 90 20 - - 8 80 80 80 80 80 8 8
40~150 100 120 145 225 285 *20 - - 8 80 100 125 205 365 8 8
200~300 145 165 190 270 430 30 15 - 10 105 125 150 230 390 30 30
400~750 145 165 190 270 430 40 20 - 10 105 125 150 230 390 30 30
800~1000 165 185 210 290 450 *60 30 - 10 115 135 160 240 400 30 30
1200~1500 165 185 210 290 450 90 21 48 10 115 135 160 240 400 30 30
1600~3000 165 185 210 290 450 120 30 60 10 115 135 160 240 400 30 60
4000~5000 165 185 220 300 460 120 30 60 15 115 135 170 250 410 60 130
6000~7500 175 195 220 300 460 154 25 52 25 125 145 170 250 410 130 130
8000~10000 185 205 - - - 206 25 52 30 135 155 180 260 420 170 -
12000~15000 185 205 - - - 310 25 52 30 135 155 180 260 420 170 -

 

Rated Current 
Amps.
Current 
Terminal 
Dim.
No. of 
Current 
Terminal
No. of 
Current 
Terminal
1~30 M 5x12 2 x 1 -
40~150 M 8x12 2 x 1 15
200~300 M 12x40 2 x 1 20
400~750 M 16x45 2 x 1 25
800~1000 M 20x50 2 x 1 40
1200~1500 M 16x45 2 x 2 40
1600~3000 M 20x50 2 x 2 40
4000~5000 M 20x50 2 x 2 40
6000~7500 M 20x75 2 x 3 40
8000~10000 M 20x85 2 x 4 40
12000~15000 M 20x85 2 x 6 40


 

Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
UPTo 30 Amps. 40 A To 150 A 200 A To 1000 A
 
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
1200 TO 3000 A 4000 A To 5000A
6000 A to 7500 A shunts 
have 3 Boltsat each terminal spaced at lateral distance B3
8000 A To 10000 A
12000 A to 15000 A shunts have 6 Bolts
at each terminal spaced at lateral distance B3
 
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
  8000 A To 10000 A
12000 A to 15000 A shunts have 6 Bolts
at each terminal spaced at lateral distance B3
 
(All Dimension are in mm)

 

Note :
1) Dimension A, E, H are the same for 50mV shunt & 60mV shunt.
2) Unless specified tolerance for mounting dimensions (Dim "E") shall be of ±1.5mm upto 1500A rating & ± 2.0mm for the rating above 1500A.
3) Maximum value of 'H' is specified, Minimum value is equal to corresponding value of 'C1'.
4) *Dimension 20 & 60mm is for 60/75mV and 25 & 70 mm respectively for 100~300mV.
5) The consumption of measuring instusments should not exceed 500 microwatts for interchangeable     shunts.

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
Ac Voltage Stabilizers, Ac Voltage Stabilizers From 1 To 3000 Kva, Analogue Panel Voltmeter With Built In Selector Switch, Anodising Plant Rectifiers, Anodising Rectifiers, Automatic Voltage Stabilizers, Built In Transducer Type Analogue Power Factor Meter, Built In Transducer Type Digital Power Meter, C. T. Testing Unit, Combimeter Digital Vif Meter, Control Transformers 50Va To 5000Va, Current And Voltage Transformer From 11Kv To 220Kv, Current Injection Test Unit, Current Injection Test Unit Upto 15000 Amp, Current Transformer, D. C. Energy Meters, Dc Energy Meter, Digital Energy Meter (Counter Type), Digital Energy Meter (Led Display And Rs 485 Interface), Digital Panel 16 Range Ammeters, Digital Power Factor Meter, Dimmerstat, Dimmerstat Continuously Variable Voltage Auto Transformer, Dpm Rms Meters, Dual Kwh Meter, Dual Kwh Meters, Dynamometric 1Ph And 3Ph Power And Power Factor Meter, Electrical Rectifier, Electrical Rectifiers, Electronic Led Frequency Meter, Electronic Rectifier, Electronic Rectifiers, Electronics Electroplating Rectifier, Electronics Plating Rectifier, Electrophoretic Rectifier, Electroplating Rectifier, Electroplating Rectifier Upto 600 Vdc Or 10000A Or 600Kva, Electroplating Rectifiers, Encapsulated Current Transformers Ae 110 (86) Series, Encapsulated Current Transformers Ae 125 (104) Series, Encapsulated Current Transformers Ae 65 (45) Series, Encapsulated Current Transformers Ae 70 (50) Series, Encapsulated Current Transformers Ae 78 (62) Series, Encapsulated Current Transformers Ae 98 (74) Series, Encapsulated Type Current Transformer, Encapsulatedcurrent Transformers Ae 155 (140) Series, Frequency Meters, Gold Plating Rectifier, Gold Plating Rectifiers, Gold Rectifiers, H. V. Tester, H. V. Tester From 2. 5 To 200 Kv, High Tension Oil Cooled Outdoor Current Transformers, High Tension Oil Cooled Outdoor Potential Transformers, High Tension Resin Cast Indoor Current Transformers, High Tension Resin Cast Indoor Potential Transformers, Industrial Electroplating Rectifiers, Industrial Plating Rectifiers, Industrial Rectifier, K. W. H. Energy Meters, Lighting Transformer, Lighting Transformer Resin Cast Upto 630Kva, Low Tension Current Transformers, Low Tension Indoortape Wound Current Transformer, Low Tension Indoortape Wound Potential Transformer, Low Tension Power Transformer, Low Tension Resin Cast Current Transformer, Low Tension Resin Cast Wound Potential Transformer, Maximum Demand Controller Mdc 1000, Maximum Demand Meter, Moving Coil 240 Long Scale Instruments, Moving Coil Ammeters And Voltmeters (Slide In Scale), Moving Coil Instruments, Moving Coil Meters, Moving Iron Ammeters And Voltmeters (Slide I Scale), Moving Iron Meters, Multi Function Meter Ae90xx With Dg Monitor And Printer, Multifunction Meter Ae9000 Ae9001 Ae9002 Ae9003 Part I, Multifunction Meter Ae9000 Ae9001 Ae9002 Ae9003 Part Ii, Multifunction Meter Ae9000 With Thd Measurement, New T Series Single Phase Transducer, P. T. Testing Unit, Phase Sequence Indicator, Plating Rectifier, Plating Rectifiers, Portable Instrument 1Ph And 3Ph Power Meter (Large Size Dynamometric In Wodden Housing), Portable Instrument D. C. And A. C. Ammeters (Large Size Precision In Wodden Housing), Portable Instrument D. C. And A. C. Ammeters (Medium Size Standard With Bake Lite Housing), Portable Instrument D. C. And A. C. Voltmeters (Large Size Precision In Wodden Housing), Portable Instruments, Power Factor Meters, Power Line Transducers, Powerling Transducers, Programmable Multifunction Transducer (Pmt 9), Programmable Multifunction Transducers, Pulse Plating Rectifier, Pulse Rectifier, Pulse Rectifiers, Rectifier Electroplating, Rectifier Plating, Rectifier Units For Electroplating And Anodising, Rectifiers Electroplating, Rectifiers For Anodizing, Rectifiers For Electroplating, Rectifiers Plating, Regular Shunts, Silver Rectifier, Smps Rectfier, Static Watthour Meter With Electro Mechanical Display, Static Watthour Meter With Led Display, Step Syn A. C. Synchronous Motor, Stepsyn, Synchroscope, Test Bench Unit, Transformer Upto 1000Kva, True Rms Onsite Programmable Digital Panel Ammeter, True Rms Onsite Programmable Digital Panel Voltmeter, Ultra Isolation Transformer, Ultra Isolation Transformer Upto 300Kva, Vibrating Reed Frequency Meter, Vif Meter Single And Three Phase, Vif Meters, Voltage Transformer, New T Series Single Phase Transducer, Portable Instrument D. C. And A. C. Voltmeters (Medium Size Standard With Bake Lite Housing), WELDING TRANSFORMERS, VARIABLE TRANSFORMER, ULTRA ISOLATION TRANSFORMERS, TRANSFORMERS, THREE PHASE TRANSFORMER, THREE PHASE TO SINGLE PHASE TRANSFORMER, STEP DOWN FURNACE TRANSFORMERS, SPECIAL PURPOSE TRANSFORMER, SINGLE PHASE TRANSFORMER, POWER TRANSFORMERS, POWER DISTRIBUTION TRANSFORMERS, POTENTIAL TRANSFORMERS, OIL TRANSFORMERS, LOW VOLTAGE TRANSFORMERS, INDUSTRIAL TRANSFORMERS, HIGH VOLTAGE TRANSFORMERS, FURNACE TRANSFORMERS, FURNACE TRANSFORMER, ELECTRICAL TRANSFORMER, ELECTRICAL POWER TRANSFORMER, DRY TYPE TRANSFORMER, DOUBLE WOUND TRANSFORMER, DISTRIBUTION TRANSFORMERS, DISTRIBUTION TRANSFORMER, CURRENT TRANSFORMERS, CONTROL TRANSFORMERS, CONTROL TRANSFORMER, AUTO WOUND TRANSFORMER